CH EN
CH
Automatic retrieval of tooling
关Key technical parameters
  • Function:Automatic access to IV test kits
  • Device beat :≤16s
  • Installation success rate:≥99.5 %
  • Device opening probability ≥99%
  • Maximum compatible size:1500*2500
  • Compatible with a variety of board types one click switch
  • Camera type: Area array HD camera
  • Tooling: Rod tooling (need Jinchen to match)
  • It is necessary to confirm with the customer in advance the winding method of the junction box and the junction box and MC4 connector cannot be eccentric
  • The incoming direction of components must be the same and the positive and negative connectors must be on the same side
  • Tooling reflux: belt transmission line


Secondary collocation information

Device name   Automatic retrieval of tooling
Weight 2000kg
Voltage 380VAC±5%
Frequency 50HZ±1%
Phases three phase
Atmospheric pressure 0.6-0.8MPA
Flow demand 40L/min
Maximum power 10kw
Connector Type Quick connect