CH EN
CH
Multifunctional electric injection station
Serial number   Project   Detail
1   Dimensions(mm)   Single station machine:800L*800W(207W discharge table not included)*1800H
Double station machine; 1200L*800W(207W discharge table not included)*1800H
Four station machine:2000L*800W(207W discharge table not included)*1800H
2   Battery temperature control range   Room temperature is adjustable to 250℃
3   Teperature control precision   CID test at 110℃ 0.5A±2%
4   Injection current   The value ranges from 0 to 10A
5   Current control accuracy   0.1A
6   Processing time   The program can be set up in 7 sections thousands of cycles and 5 sets of processing processes can be pre-stored
7   Slide mode   Hand loading and unloading
8   Number of sheets per station and battery size   Number of lamination:10-120片,The specific number of laminates is determined by the current size and the actual situation of the battery.
Cell size:166-220mm(Three sets of material box bottom plate are provided:166mm182mm210mm)
9   Process monitoring parameter   The voltage current and temperature at both ends of electrode are displayed in real time
10   Power supply   AC220V±10%,50Hz±1,Two-phase three-wire system grounding resistance is less than 4Ω(Suitable for single and double stations)
AC380V±10%,50Hz±1,Three-phase five-wire system grounding resistance less than 4Ω(Suitable for four stations)
11   Equipment power   Single station machine:3KW
Double station machine:6KW
Four station machine*12KW
12   Uptime   98.5%